Calendar · Newsletters · Events  
About the City Business Government Residents Departments Online Services
Engineering Redwood City, California
     Home » Building, Infrastructure, and Transportation » Infrastructure » Standards » Standard Specifications


Engineering Standards

Data & Maps

Permits & Forms

Fees & Charges

Projects

Prevailing Wages

FAQ

 


Standard Specifications

Legend Notes, Abbreviations

AA - 1 Improvement Plan Legend
AA - 2 Improvement Plan Abbreviations

Streets
A - 1a | 1b Standard Street Sections: 1| 2
A - 2 Omitted
A - 3a | 3b | 3c Design Criteria for Private Streets: 1 (No Parking) | 2 (Parking Bays) | 3 (Curb and Gutter)
A - 4a | 4b Limited Right-of-Way Street Section and Parking Bay: 1 (Street Section) | 2 (Parking Bay)
A - 5 Cul-De-Sac
A - 6 Asphalt Planing
A - 7 Speed Hump

Curb, Gutters, Sidewalks, Driveways
C - 1a | 1b Residential Driveway: 1 (Plan, Elevation) | 2 (Sections)
C - 2 Commercial Driveway
C - 3 Curb and Gutter
C - 4 Sidewalk Detail (Monolithic)
C - 5 Sidewalk Detail (Parkway)
C - 6 Median Treatment
C - 7 Curb Drain (in existing curb and sidewalk)
C - 8 Curb Drain (in new curb and sidewalk)
C - 9 Omitted
C - 10 Bus Stop and Turnout
C - 11 Sidewalk Repair Requirements
C - 12 Omitted

Drainage
D - 1a | 1b Curb Inlet: 1 (Top) | 2 (Base)
D - 2a | 2b Junction Box / Area Drain: 1 | 2
D - 3 Omitted
D - 4 Omitted
D - 5 Lagoon Dewatering Structure
D - 6 Flared End Section
D - 7 Pipe Connection
D- 8a | 8b Combination Catch Basin/ Inlet and Curb and Gutter: 1 | 2
D - 9 Mounting Plaque for Inlet Labeling

Electrical/Street Lighting
E - 3 Street Light (Single)
E - 3D Street Light (Double)
E - 4 Street Light Footing
E - 7 Street Light (Redwood Shores)

Monuments and Manholes
M - 1 Standard Street Monument (Placement and Casting)
M - 2 Standard Survey Monument (Installation in Marsh or Unstable Soil)
M - 3 Type I Manhole (Pipes 6" to 21")
M - 4 Type II Manhole (Pipes 24" to 48")
M - 5 Type III Manhole (Pipes Larger Than 48")
M - 6 Manhole Frame and Cover
M - 7 Manhole Step for Precast Manhole

Sewer
S - 1a | 1b Sanitary Sewer Lateral (New Connection to Existing Main) 1 | 2
S - 2 Sanitary Sewer Lamphole
S - 3a | 3b Sanitary Sewer Lateral (New HDPE SDR 17 Connect. to New HDPE SDR 17 Main) 1 | 2
S - 4a | 4b Sanitary Sewer Lateral (New HDPE SDR 17 Connect. to Exist. VCP Main with New CIPP Liner) 1 | 2
S - 5a | 5b Sanitary Sewer Lateral (New PVC SDR 26 Connect. to Exist. VCP Main with New CIPP Liner) 1 | 2
S - 6a | 6b Sanitary Sewer Lateral (New HDPE SDR 17 Connect. to New PVC SDR 26 Main) 1 | 2
S - 7a | 7b Sanitary Sewer Lateral (New PVC SDR 26 Connect. to New PVC SDR 26 Main) 1 | 2

Traffic Control
T - 1 Omitted
T - 2 Omitted
T - 3 Omitted
T - 4 Break-Away Sign Post
T - 5 Street Name Sign
T - 6 Sign Installation Plans
T - 7 Pavement Markers
T - 8 Parking Meter Installation
T - 9 Red Curb Painting
T - 10 Median Tapers
T - 11 Omitted
T - 12 Wheel Stop

Utility Trench Details
UT - 1 Utility Trench
UT - 2 Utility Trench (Bay Mud)
UT - 3 Rockwheel Trench

Water Details
W - 1 Above Ground Combination Air Release and Vacuum Valve
W - 2 1" By-Pass for Closed Gate Valve
W - 3 1 1/2" or 2" Plastic Service Connection
W - 4 2" Blow Off
W - 5 2" Polyethylene Loop
W - 6 Fire Hydrant
W - 7 Thrust Blocks
W - 7A Vertical Bend Anchor
W - 8a | 8b Thrust Blocks (in Bay Mud): 1 | 2
W - 9 Excavation for Tapping Sleeves and Valves
W - 10 Locator Wire
W - 11 Valve Stem Extension
W - 12 Valve Box and Riser
W - 13A Fire Service (Reduced Pressure Principle Backflow Prevention Assembly)
W - 13B Fire Service (System Layout Plan)
W - 14 Cathodic Protection at Fittings and Valves
W - 15 Fire Hydrant (In Bay Mud)
W - 16 Cathodic Protection Test Station Housing
W - 17 Reduced Pressure Principle Backflow Prevention Device (Domestic and Commercial Potable Water Service)
W - 18 Cathodic Protection Exothermic Weld
W - 19a | 19b Pipe Anchors and Trench Stabilizers: 1 | 2
W - 20A Water Main Bends
W - 20B Thrust Restraint Length Table
W - 20C Joint Restraint with Petrolatum Tape System
W - 20D Water Main Lowering Detail
W - 21 Capping Active Line For Existing Plain End Pipe)
W - 22 Cut and Plug Inactive Line
W - 23 Gate Valves and Butterfly Valves Joint Types and Adapters

Landscaping and Irrigation Details
Z - 1a | 1b Reduced Pressure Backflow Prevention Device - Irrigation Only 1 | 2
Z - 2 Pop-up Irrigation Head
Z - 3 Quick Coupler Valve
Z - 4 Omitted
Z - 5 Remote Control Valve
Z - 6 Omitted
Z - 7 Gate Valve (Irrigation System)
Z - 8 Irrigation Controller
Z - 9 Irrigation Trench Backfill
Z - 10 Ground Cover Planting
Z - 11 Plastic Lumber Header (Landscape Areas)
Z - 12 Shrub Planting on Slopes
Z - 13a | 13b Street Tree Planting: 1 | 2
Z - 14 Tree Protection Detail
Z - 15a | 15b Tree Well Detail: 1 | 2
Z - 16a | 16b Drinking Fountain: 1 | 2

Utilities Located on or Near Closed Landfill Areas
LF - 1 Utility Trench Penetrating Clay Cap
LF - 2 Utility Structure Penetrating Clay Cap
LF - 3 Methane Gas Cut-off Barrier in Utility Trench
LF - 4 Leak Detection Vault at Water Valves and Water Service Connections Main
LF - 5 Sanitary Sewer Gravity Pipes Thru Transition Zone
LF - 6 Termination of Containment Pipe at Limits of Refuse
LF - 7 Containment Pipe Termination Structure
LF - 8 Pressure Pipe Enclosed in Containment Pipe
LF - 9 Termination of Containment Pipe at Air Release Valve
LF - 10 Termination of Containment Pipe at Water Meter Box and Detector Check Valve Box
LF - 11 Termination of Containment Pipe at Fire Hydrant
LF - 12 Termination of Containment Pipe at Blow-Offs

 

 

 

HomeCareersCalendarContact UsSitemapFollow Us  

Logo 2015 City of Redwood City
Terms of Service | Comments and Suggestions